Preview

Transplantologiya. The Russian Journal of Transplantation

Advanced search

Potential of X-ray endovascular technologies in the correction of rare vascular complications after kidney transplantation

https://doi.org/10.23873/2074-0506-2024-16-4-483-490

Abstract

Objective. The paper aims at demonstrating the efficacy of endovascular interventional techniques in the treatment of rare vascular complications after kidney transplantation.

Material and methods. Recipients of renal grafts obtained from a deceased donor developed the following complications: a false aneurysm of the interlobar renal artery after lymphocele puncture in one case and a subintimal hematoma of the external iliac artery with subocclusion of the latter and impaired perfusion of the renal graft in the other one.

Results. These complications were successfully managed using X-ray endovascular technologies, which allowed saving the renal grafts in both cases with satisfactory long-term results.

Conclusion. Early diagnosis and endovascular technologies made it possible to cope with complications minimally invasively and prevent the development of adverse events in the long term.

About the Authors

A. V. Shabunin
Moscow Multidisciplinary Scientific and Clinical Center n.a. S.P. Botkin; Russian Medical Academy of Continuous Professional Education
Russian Federation

Aleksey V. Shabunin - Academician of the Russian Academy of Sciences, Prof., Dr. Sci. (Med.), Director of Moscow Multidisciplinary Scientific and Clinical Center n.a. S.P. Botkin; Head of the Department of Surgery, RMACPE.

5 2-nd Botkinskiy Dr., Moscow 125284; 2/1 Bldg. 1 Barrikadnaya St., Moscow 125993



V. V. Bedin
Moscow Multidisciplinary Scientific and Clinical Center n.a. S.P. Botkin; Russian Medical Academy of Continuous Professional Education
Russian Federation

Vladimir V. Bedin - Dr. Sci. (Med.), Deputy Director for Innovative Development, Moscow Multidisciplinary Scientific and Clinical Center n.a. S.P. Botkin; Associate Professor the Department of Surgery, RMACPE.

5 2-nd Botkinskiy Dr., Moscow 125284; 2/1 Bldg. 1 Barrikadnaya St., Moscow 125993



A. V. Arablinskii
Moscow Multidisciplinary Scientific and Clinical Center n.a. S.P. Botkin
Russian Federation

Aleksandr V. Arablinskii - Dr. Sci. (Med.), Head of the Department of X-ray Endovascular Methods of Diagnostics and Treatment.

5 2-nd Botkinskiy Dr., Moscow 125284



M. G. Minina
Moscow Multidisciplinary Scientific and Clinical Center n.a. S.P. Botkin
Russian Federation

Marina G. Minina - Professor of the Russian Academy of Sciences, Dr. Sci. (Med.), Head of the Moscow Coordination Center of Organ Donation.

5 2-nd Botkinskiy Dr., Moscow 125284



V. A. Tsurkan
Moscow Multidisciplinary Scientific and Clinical Center n.a. S.P. Botkin
Russian Federation

Vladimir A. Tsurkan - Interventional Radiologist of the Department of X-ray Endovascular Methods of Diagnostics and Treatment.

5 2-nd Botkinskiy Dr., Moscow 125284



P. A. Drozdov
Moscow Multidisciplinary Scientific and Clinical Center n.a. S.P. Botkin; Russian Medical Academy of Continuous Professional Education
Russian Federation

Pavel A. Drozdov - Dr. Sci. (Med.), Deputy Director for Science, Moscow Multidisciplinary Scientific and Clinical Center n.a. S.P. Botkin; Associate Professor of the Department of Surgery, RMACPE.

5 2-nd Botkinskiy Dr., Moscow 125284; 2/1 Bldg. 1 Barrikadnaya St., Moscow 125993



I. V. Nesterenko
Moscow Multidisciplinary Scientific and Clinical Center n.a. S.P. Botkin; Russian Medical Academy of Continuous Professional Education
Russian Federation

Igor V. Nesterenko - Dr. Sci. (Med.), Surgeon of Department of Organ and/or Tissue Transplantation.

5 2-nd Botkinskiy Dr., Moscow 125284; 2/1 Bldg. 1 Barrikadnaya St., Moscow 125993



A. Kh. Tseloeva
Moscow Multidisciplinary Scientific and Clinical Center n.a. S.P. Botkin
Russian Federation

Aza Kh. Tseloeva - Anesthesiologist-Intensivist, Head of the Department of Extracorporeal Circulation Techniques.

5 2-nd Botkinskiy Dr., Moscow 125284



Yu. V. Kolbasova
Moscow Multidisciplinary Scientific and Clinical Center n.a. S.P. Botkin
Russian Federation

Yulia V. Kolbasova - Medical Ultrasonologist, Functional Diagnostics Department.

5 2-nd Botkinskiy Dr., Moscow 125284



L. P. Semenova
Moscow Multidisciplinary Scientific and Clinical Center n.a. S.P. Botkin
Russian Federation

Lubov P. Semenova - Anesthesiologist-Intensivist, Department of Extracorporeal Circulation Techniques.

5 2-nd Botkinskiy Dr., Moscow 125284



E. Yu. Vetlugina
Moscow Multidisciplinary Scientific and Clinical Center n.a. S.P. Botkin
Russian Federation

Ekaterina Yu. Vetlugina - Anesthesiologist-Intensivist, Department of Extracorporeal Circulation Techniques.

5 2-nd Botkinskiy Dr., Moscow 125284



References

1. Gautier SV. Transplantology of the 21st century: High technology in medicine and innovation in biomedical science. Russian Journal of Transplantology and Artificial Organs. 2017;19(3):10–32. (In Russ.). https://doi.org/10/15825/19951191-2017-3-10-32

2. Khubutiya MSh, Lonshakov DV, Balkarov AG, Anisimov YuA, Shmarina NV, Zagorodnikova NV, et al. Experience in the treatment of a primary infected kidney transplant. Transplantologiya. The Russian Journal of Transplantation. 2023;15(2):216–225. (In Russ.). https://doi.org/10.23873/2074-05062023-15-2-216-225

3. Ozban M, Aydin C, Dursun B, Yagci B, Birsen O, Tekin K. Post-kidney transplantation external iliac artery stenosis due to vascular clamp: report of a case. Jornal Vascular Brasileiro. 2014;13(3):254–256. https://doi.org/10.1590/jvb.2014.037

4. Reyna-Sepúlveda F, Ponce-Escobedo A, Guevara-Charles A, Escobe do-Villarreal M, Pérez-Rodríguez E, Muñoz-Maldonado G, et al. Outcomes and surgical complications in kidney transplantation. Int J Organ Transplant Med. 2017;8(2):78–84. PMID: 28828167

5. Shabunin AV, Drozdov PA, Tsurkan VA, Nesterenko IV, Makeev DA, Zhuravel OS, et al. Immediate and long-term results of the use of balloon angioplasty with stenting in the treatment of renal graft arte rial stenosis. Transplantologiya. The Russian Journal of Transplantation. 2023;15(2):168–176. (In Russ.). doi.org/10.23873/2074-0506-2023-15-2168-176

6. Korobka VL, Kostrykin MYu, Malevanny MV, Kotov OV, Korobka RV, Pak ES, et al. Treatment of vascular complications following orthotopic liver transplantation. The experience of a regional centre. Russian Journal of Transplantology and Artificial Organs. 2023;25(4):22–31. (In Russ.). https://doi.org/10.15825/1995-1191-2023-4-22-31

7. Dukhanina IV, Bagatelia ZA. Flow analysis for urgent surgical patients with diseases of abdominal cavity organs. Fundamental research. 2015;1–5:938–940. (In Russ.).


Review

For citations:


Shabunin A.V., Bedin V.V., Arablinskii A.V., Minina M.G., Tsurkan V.A., Drozdov P.A., Nesterenko I.V., Tseloeva A.Kh., Kolbasova Yu.V., Semenova L.P., Vetlugina E.Yu. Potential of X-ray endovascular technologies in the correction of rare vascular complications after kidney transplantation. Transplantologiya. The Russian Journal of Transplantation. 2024;16(4):483-490. https://doi.org/10.23873/2074-0506-2024-16-4-483-490

Views: 234


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 2074-0506 (Print)
ISSN 2542-0909 (Online)